USE WITH REMOTE-CONTROLLER:

You can open and close shutters with remote-controller by pressing button once.The shutter automatically stops when it comes to the level of opening and closing. There is no need to press the button again. If it is neccessary to stop urgently, you can press the button once. Pressing the button again makes the shutter move opposite direction.

Important Note: Before use of door with remote controller, please control the movement area of the door for the life safety, security of product and building. If there is a balk, remove it. And please watch the shutter until the it completes its movement.


USE WITH SHUTTER SWITCH:

In use with shutter switch, you can make the shutter move with turning the switch to one of the directions. The shutter automatically stops when it comes to the level of opening and closing. If it is neccessary to stop urgently, you can bring the switch to "0" point. And please watch the shutter until the it completes its movement..


USE WITH BUTTON:

In use with button, you can make the shutter move with pressing one of the directions on the button. The shutter automatically stops when it comes to the level of opening and closing. If it is neccessary to stop urgently, release the button. Please do not press two buttons at the same time.
Manual Use
USE WITH BREAK-RELEASE BOX IN CENTRAL ENGINES

In case of power cuts or manual uses, you should open the box mounted on the wall near the shutter with the key given during montage. While you turn the handle in the box to the opposite direction by 180° (Picture 2), shutter can be lift by hands and you can lift it with your hand force by holding the shutter from its both sides. After the shutter is lift enough, you should bring the handle to the previous position. When the power cut ends, you should follow normal use (with remote controller, with button or with shutter switch) process. After manual use do not forget to bring the mechanism to the previous position, and lock the box. (Picture 1) To close the shutter, you should proceed same operation.

Important Note: In manual use of shutter, be careful about balance of the shutter on up-down movement. While you open it by hand force, prevent it to hit the ground or the top strongly.


USE WITH INTERIOR BREAK-RELEASE WIRE IN CENTRAL ENGINES

During power cuts or manual use, you should handle the bottom side of the plastic mechanism hanging down near the shutter, and you should turn the plastic component on the top of this mechanism counter-clockwise. When plastic component is turned enough (Picture 4 - about 3-4 cm), shutter can be lift by hands and you can lift it with your hand force by holding the shutter from its both sides.





Installation and Safe Use
- You should make your shutter installed by an expert electirician.

- You should control the compatibility between engine power of the shutter, feeding line section and feeding line fuse. You should also check compatibility between engine voltage and network voltage..

- You should ensure that electricity line is grounded.

- After the shutter is lift enough, you should close the plastic mechanism to bring the shutter to the previous position.
When the power cut ends, you should follow normal use (with remote controller, with button or with shutter switch) process.

- After manual use do not forget to bring the mechanism to the previous position. To close the shutter, you should proceed same operation.

IMPORTANT NOTE:
In manual use of shutter, be careful about balance of the shutter on up-down movement. While you open it by hand force, prevent it to hit the ground or the top strongly.